درباره ما

VolPort، شرکت پیشرو در صنایع سنگ شکن و آسیاب چینی، در 30 سال گذشته همواره به توسعه سنگ شکن های سنگ معدن، ماشین آلات شن و ماسه سازی و آسیاب های صنعتی اختصاص داده شده است.

با ما تماس بگیرید

محصول

ما محصول

سنگ شکن موبایل

ما محصول

سنگ شکن فکی پیو

ما محصول

سنگ شکن VSI

Myocardial perfusion imaging with PET

Of several available PET tracers, 82 Rb, 13 NH 3, and H 2 15 O are the most commonly used for the assessment of myocardial perfusion . Additionally, 18 F-flurpiridaz is an emerging perfusion tracer which holds great clinical potential but is not yet available for clinical use and is currently being tested in phase 3 trials [ 7 – 9 ].

Generator-produced rubidium-82 positron emission tomography myocardial

Rubidium-82 ((82)Rb) is a generator-produced PET myocardial perfusion tracer and has been widely used in North America in clinical practice. (82)Rb PET has recently become available in some ...

Primary breast cancer diagnosed by 82-Rubidium myocardial perfusion …

82-Rubidium (82 Rb) is a photon-emitting radionuclide utilized in positron emission tomography (PET) myocardial perfusion imaging (MPI) for the detection of myocardial ischemia.The isotope, with its short half-life of 1.3 minute, is especially handy as it is produced in a small generator and not in a cyclotron.

Exponential dosing to standardize myocardial perfusion …

Background. 82 Rb PET is commonly performed using the same injected activity in all patients, resulting in lower image quality in larger patients. This study compared 82 Rb dosing with exponential vs proportional functions of body weight on the standardization of myocardial perfusion image (MPI) quality.. Methods. Two sequential cohorts of N = 60 …

Static CT myocardial perfusion imaging: image quality, …

Rubidium-82 positron emission tomography (82 Rb PET) MPI is considered a noninvasive reference standard for the assessment of myocardial perfusion in coronary artery disease (CAD) patients. Our main goal was to compare the diagnostic performance of static rest/ vasodilator stress CT myocardial perfusion imaging (CT-MPI) to stress/ rest …

Automated Motion Correction for Myocardial Blood Flow …

Abstract. Motion correction (MC) affects myocardial blood flow (MBF) measurements in 82 Rb PET myocardial perfusion imaging (MPI); however, frame-by-frame manual MC of dynamic frames is time-consuming. This study aims to develop an automated MC algorithm for time–activity curves used in compartmental modeling and …

Prompt-gamma compensation in Rb-82 myocardial perfusion 3D PET…

Retrospective, single center study of 76 patients who had rest and adenosine stress Rb-82 myocardial perfusion 3D PET. All studies were acquired using a Siemens Biograph-40 PET/CT scanner and were ...

Coronary Microvascular Disease Assessed by …

The use of 82‐rubidium positron emission tomography (82 Rb PET) myocardial perfusion imaging (MPI) provides noninvasive absolute measures of microvascular flow reserve (MFR), in addition to …

Cardiac PET Procedure: Perfusion, Coronary Flow, Viability

PET myocardial perfusion imaging (MPI) with various tracers such as Rb-82, N-13 ammonia, and O-15-H 2 O has higher sensitivity and specificity than myocardial perfusion SPECT for the detection of coronary artery disease (CAD). Advances in positron emission tomography technology have expanded the application of cardiac PET …

Myocardial Perfusion Scan, Stress | Johns Hopkins Medicine

Request an Appointment. 410-955-5000 Maryland. 855-695-4872 Outside of Maryland. +1-410-502-7683 International. Find a Doctor. A stress myocardial perfusion scan is used …

Myocardial Perfusion Imaging Test | American Heart …

Last Reviewed: Aug 18, 2023. Myocardial perfusion imaging (MPI) is a non-invasive imaging test that shows how well blood flows through your heart muscle. It can show …

Myocardial perfusion scintigraphy using rubidium-82 …

Both require an on-site cyclotron and so the generator produced 82 Rb is now more commonly used. 9 Various software applications are available for the quantification of myocardial perfusion using 82 Rb PET and the results compare favorably with other validated methods. 10–12 The normal ranges for stress and rest perfusion vary …

Flurpiridaz F-18 PET Myocardial Perfusion Imaging in …

Results. A total of 578 patients (age 63.7 ± 9.5 years) were evaluable; 32.5% were women, 52.3% had body mass index ≥30 kg/m 2, and 33.6% had diabetes.Flurpiridaz PET met the efficacy endpoints of the study; its sensitivity and specificity were significantly higher than the prespecified threshold value by 2 of the 3 readers.

Myocardial Flow Reserve, an Independent Prognostic Marker …

In the current clinical practice, rubidium-82 positron emission tomography (82 Rb PET) myocardial perfusion imaging (MPI) is a widely acknowledged, first-line, …

Flurpiridaz F-18 PET Myocardial Perfusion Imaging in …

Background: Flurpiridaz F-18 (flurpiridaz) is a novel positron emission tomography (PET) myocardial perfusion imaging tracer. Objectives: The purpose of this study was to further assess the diagnostic efficacy and safety of flurpiridaz for the detection and evaluation of coronary artery disease (CAD) defined as ≥50% stenosis by …

PET Myocardial Perfusion Imaging: 82 Rb

Rubidium 82 ( 82 Rb) is a positron emitter tracer, produced by the nuclear decay of Strontium-82 by electron capture via a commercially available generator. It is used for PET myocardial perfusion imaging (MPI) and quantification of myocardial blood flow (MBF) that has been shown accurate despite the limits of quantification intrinsic to non ...

Stress Myocardial Perfusion Imaging for Assessing …

A strength of nuclear myocardial perfusion imaging (MPI) is the wealth of prognostic data accumulated over 30 years of experience with this technique. ...

Diagnostic and prognostic significance of transient ischemic …

Myocardial perfusion Imaging ... (2 studies), dual isotope scanning (2 studies), and Rb-82 (1 study). Coronary angiography was performed in 73% of patients. The modality of stress included exercise (4 studies), pharmacologic stress (6 studies), and both exercise and pharmacologic stress (3 studies).

Heart Perfusion Imaging Scan: What You Should Know

The heart perfusion scan can be done when your heart is at rest or during physical activity. The test during physical activity is often known as a stress test. During that stress test, you walk or ...

Prompt-gamma compensation in Rb-82 myocardial perfusion …

PET imaging technology allows for absolute and relative myocardial blood flow analysis. In addition to the well-known positron emissions resulting in the production of annihilation radiation usually in the form of two 511 keV photons used for PET imaging, Rb-82 also emits 776 keV gamma rays with 13% abundance known as prompt gamma …

Myocardial perfusion scan

What happens during a myocardial perfusion scan? Myocardial perfusion scans are usually divided into two parts – 'stress' and 'rest'. This helps doctors see the effects of stress (exercise) on your heart. For the 'stress' part of the test, you will be asked to exercise on a bike or treadmill. If you can't do this, you may be ...

Nuclear stress test

A nuclear stress test is an imaging test that shows how blood goes to the heart at rest and during exercise. It uses a small amount of radioactive material, called a tracer or radiotracer. The substance is …

Nuclear Medicine PET Scan Cardiovascular Assessment, …

The hybrid CT scan can be used to correct attenuation artifacts and scattering of PET data, which allows an accurate measurement of myocardial perfusion. Radiotracers. Perfusion Tracers: Although there are multiple radiotracers available worldwide, rubidium-82 (Rb) and nitrogen-13-ammonia (N-ammonia) are most …

Recent Progress in Myocardial Perfusion Imaging Techniques

Myocardial perfusion imaging (MPI), an important component of nuclear cardiology that commenced in the 1970s, plays a crucial role in the non-invasive evaluation and management of coronary artery disease. ... Jager PL, van Osch JAC, Khodaverdi M, van Dalen JA. Comparison of maximal rubidium-82 activities for myocardial blood flow …

Simulation of Low-Dose Protocols for Myocardial Perfusion

Abstract. Quantification of myocardial perfusion and myocardial blood flow using 82 Rb PET is increasingly used for assessment of coronary artery disease. Current guidelines suggest injections of 1,100–1,500 MBq for both stress and rest. Reducing the injected dose avoids PET system saturation in first-pass flow images and reduces …

Myocardial Perfusion Scan

In PET imaging, radiotracers such as ammonia N-13, rubidium-82, and flurpiridaz F-18 are radiotracers used in for …

In 2023 PET myocardial perfusion imaging is preferred to

In 2023 PET myocardial perfusion imaging is preferred to invasive coronary angiography for the initial work-up of a symptomatic patient with a high coronary artery calcium score ... reducing Compton scatter and non-uniform attenuation. The most commonly used PET tracer, 82 Rb, has a short half-life allowing higher doses and …

Value of SiPM PET in myocardial perfusion imaging using Rubidium-82

However, the effect on image quality and visibility of perfusion defects in myocardial perfusion imaging (MPI) is unknown. Our aim was to determine the value of a SiPM PET scanner in MPI. We prospectively included 30 patients who underwent rest and regadenoson-induced stress Rubidium-82 (Rb-82) MPI on the D690 PMT PET (GE …

Myocardial perfusion quantification with Rb-82 PET: good …

Purpose: To estimate the interobserver agreement of the Carimas software package (SP) on global, regional, and segmental levels for the most widely used myocardial perfusion PET tracer-Rb-82. Materials and methods: Rest and stress Rb-82 PET scans of 48 patients with suspected or known coronary artery disease (CAD) were analyzed in four centers …

Myocardial perfusion scintigraphy using rubidium-82 …

Assessment of absolute myocardial perfusion may provide insight into the effects of traditional risk factors on perfusion reserve and the impact of risk factor modifications on progression of coronary artery disease. Myocardial perfusion scintigraphy using rubidium-82 positron emission tomography Br Med Bull. 2013;107:87-100. doi: 10.1093 /bmb ...

Myocardial perfusion imaging

Myocardial perfusion imaging scans are "powerful predictors of future clinical events", and in theory may identify patients for whom aggressive therapies should improve outcome. ... Many radionuclides used for myocardial perfusion imaging, including rubidium-82, technetium-99m and thallium-201 have similar typical effective doses (15-35 mSv).

The utility of 82Rb PET for myocardial viability assessment: …

Background: 82 Rb kinetics may distinguish scar from viable but dysfunctional (hibernating) myocardium. We sought to define the relationship between 82 Rb kinetics and myocardial viability compared with conventional 82 Rb and 18 F-fluorodeoxyglucose (FDG) perfusion-metabolism PET imaging.. Methods: Consecutive patients (N = 120) referred for …

Noninvasive Assessment of Myocardial …

Myocardial perfusion imaging with CT is based on the intravenous injection of iodinated contrast agents that increase the absorption of x-rays in proportion to the concentration of iodine. 81 Most of the agents used …

Cardiac perfusion by positron emission tomography

by conventional positron emission tomography (PET) or single photon emission computed tomography (SPECT), absolute quan-tification of the global and regional myocardial blood flow (MBF) by PET obviates the drawbacks of overlooking global reduction of myocardial perfusion or underestimating the true extent of myo-cardial …

Combined evaluation of regional coronary artery calcium and myocardial …

The combined use of CAC, myocardial perfusion imaging and quantitative coronary vascular function in may help predict more accurately the presence of obstructive CAD. ... Methods: We analyzed 113 patients with suspected CAD referred to 82 Rb PET/CT myocardial perfusion imaging with available coronary angiographic data. Obstructive …

Myocardial blood flow quantification by Rb-82 cardiac …

Introduction. Myocardial perfusion imaging is an important step for diagnosis and management of coronary artery disease. Cardiac positron emission …

Myocardial perfusion quantification with Rb-82 PET: good …

Myocardial perfusion imaging with PET enables quantification of the myocardial blood flow (MBF) in absolute terms (mL/min/g). The three clinically available PET perfusion tracers are O-15 water, N-13 ammonia, and Rb-82—the latter being the most widely used [], likely because its production does not require an on-site …

PET and SPECT Tracers for Myocardial Perfusion Imaging

82 Rb is produced from a 82 Sr/ 82 Rb generator that has a shelf-life of 4-8 weeks, depending on the supplier. 6 It has an ultra-short half-life of 75.5 seconds. 7 Therefore, perfusion imaging typically starts 1.5-2 minutes following injection, with 94% of the total recorded counts acquired within the first 5 minutes. The short half-life ...

A systemic review of rubidium-82 PET contrasted with …

Myocardial perfusion imaging (MPI) in both SPECT and PET have long been used and regarded as a standard examination for coronary artery disease in hospital settings. ... Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: comparison with ECG-gated Tc-99m sestamibi SPECT. J Nucl Cardiol. 2006b; …