درباره ما

VolPort، شرکت پیشرو در صنایع سنگ شکن و آسیاب چینی، در 30 سال گذشته همواره به توسعه سنگ شکن های سنگ معدن، ماشین آلات شن و ماسه سازی و آسیاب های صنعتی اختصاص داده شده است.

با ما تماس بگیرید

محصول

ما محصول

سنگ شکن موبایل

ما محصول

سنگ شکن فکی پیو

ما محصول

سنگ شکن VSI

High-precision multidynamic Sr isotope analysis using thermal …

Strontium isotopic analyses were performed at the Australian National University using a Thermo Scientific Triton Plus multicollector thermal ionization mass spectrometer. The measurement condition and cup configuration used are listed in Table 1.Before measurement, the filaments were preheated to 2500 mA (ca. 1380 °C) in 50 min …

Precise measurements of trace neodymium isotopes as Nd+ ions by thermal

Neodymium isotope analysis as Nd + ions is more favored than as NdO + ions due to less potential isobaric interferences and no need for complicated oxygen isotope corrections. However, the poor sensitivity and inadequate reproducibility seriously hinder its application. In this study, a new analytical method by thermal ionization mass …

Design and development of a compact thermal ionization mass

A new compact thermal ionization (TI) mass spectrometer, for the isotope ratio analysis of the elements relevant to nuclear applications, has been designed and developed. The new development offers superior performance in terms of sensitivity, precision and a compact footprint in comparison with the conventional one. The main …

Thermal Ionization Mass Spectrometry (TIMS)

Thermal ionization mass spectrometry (TIMS) is designed to obtain high precision isotopic information. Ions are created by passing a current through a thin metal ribbon or ribbons under vacuum. The ions generated are accelerated under vacuum to a magnetic …

Thermal Ionization Mass Spectrometer | Central Laboratory

Instrument: TRITON TI Mass Spectrometer. The device has been designed for a very sensitive analysis of radiogenic isotopes. It is generally used to measure isotope ratios and determine elemental concentrations in Rb-Sr, Sm-Nd, and U-Pb systems. Sample Preparation and Measurement. The general principles of radiogenic isotope …

Thermal Ionization Mass Spectrometry (TIMS)

What is Thermal Ionization Mass Spectrometry (TIMS) A TIMS is an instrument that measures isotopic ratios that are used in geochemistry, geochronology, and cosmochemistry. Fundamental …

Triton™ Series Multicollector Thermal Ionization …

Triton™ Series Multicollector Thermal Ionization Mass Spectrometer. Catalog number: IQLAAEGAASFAFYMAMV. Related applications: Mass Spectrometry. Technical Support Customer Service. Extract high …

2.3: Ionization Techniques

Ionization occurs by charge transfer between the ions and the sample or by protonation from the matrix material (Figure 2.3.4 2.3. 4 ). Both solid and liquid samples may be analyzed. A unique aspect of these techniques for analysis of solids is the ability to do depth profiling because of the destructive nature of the ionization technique.

Thermal Ionization Mass Spectrometry (TIMS)

Fundamental Principles of Thermal Ionization Mass Spectrometry (TIMS) A TIMS is a magnetic sector mass spectrometer that is capable of making very precise measurements of isotope ratios of elements that can be ionized thermally, usually by passing a current through a thin metal ribbon or ribbons under vacuum. The ions created …

Mass spectrometry

Thermal ionization. Atoms with low ionization potentials can be ionized by contact with the heated surface of a metal, generally a filament, having a high work function (the …

Thermal Ionisation Mass Spectrometry

A modified thermal ionization mass spectrometer with deceleration components was tested with 234 U/ 238 U standards and on 230 Th/ 232 Th samples (Van Calsteren and Schwieters, 1995). The method of total evaporation has been tested with U and Pu samples in a thermal ionization quadrupole mass spectrometer (Fiedler, 1995). 2.

Composition of Ultrafine Particles in Urban Beijing: …

The thermal desorption chemical ionization mass spectrometer (TDCIMS) can semicontinuously measure UFP composition at the molecular level. We modified a TDCIMS and deployed it in urban Beijing. Radioactive materials in the TDCIMS for aerosol charging and chemical ionization were replaced by soft X-ray ionizers so that it can be operated …

An improved ion source for thermal ionization mass spectrometer

1. Introduction. The thermal ionization mass spectrometry (TIMS), owing to its sensitivity, selectivity and precision, is the widely accepted analytical technique for precise and accurate measurements of isotope ratios of various elements in the periodic table [1], [2], [3], [4].TIMS is the work horse for many strategic applications in the nuclear …

Thermal Ionization Mass Spectrometry (TIMS)

Summary A mass spectrometer for elemental and isotopic analysis is made of four units, namely the ion source, the mass separator, the detector, and the vacuum …

Thermal Ionization Mass Spectrometry

Thermal Ionization Mass Spectrometry. TIMS is a firmly established technique for the precise and accurate determination of isotope ratios and amounts of individual …

Thermal Ionization Mass Spectrometry | SpringerLink

A thermal ionization mass spectrometer consists of four main components : an ion source, a series of electrically charged plates used to focus and accelerate ions generated from the source, an electromagnet surrounding a "flight tube" through which the accelerated ions travel, and a detector system for measuring the intensity of ion beams ...

DG60 TIMS Thermal Ionization MS | Isotopx

Product Description. The Isotopx DG60 is a floor-standing, self-contained filament-degassing unit capable of automatically preparing up to 60 TIMS filaments per cycle. With an ultimate vacuum of 10 -8 mbar and easy-to-use software, the degassing of filaments becomes a controlled, reproducible, and hands-off process.

Thermal Ionization Mass Spectrometry

(I) Thermal Ionization Mass Spectrometry (TIMS) Thermal Ionization Mass Spectrometry (TIMS) is the most precise analytical technique used for geochronological purposes due to several factors such ...

Finnigan MAT 262 TIMS | SIGMA Shared Lab Facility

The Thermal Ionization Mass Spectrometer is used for high-precision isotope ratio measurements. Thermal Ionization Mass Spectrometry (TIMS) is used for very precise isotope ratio measurements. Purified samples are thermally ionized by passing a current through a thin metal filament (or filaments). Mass resolved ion beams are directed into ...

TIMS: Thermal Ionisation Mass Spectrometry

Product overview - TIMS is a Thermal Ionisation Mass Spectrometer. The instrument has been developed using our field-proven variable dispersion multi-collector technology to improve the versatility and overall …

(PDF) Thermal Ionisation Mass Spectrometry (TIMS) in

the thermal ionization mass spectrometer and also to check. routinely the performance of the system. A variety of CRMs are. available from Institute for Reference Materials and Measure-

Thermal Ionization Mass Spectroscopy

Metamorphic rims on zircons, not only in the Square Terrane, but also throughout the Tugaloo Terrane, along with deformed 366-My-old plutons in the Square Terrane, indicate peak metamorphism occurred from 360–350 Ma. U/Pb thermal ionization mass spectroscopy (TIMS) ages on monazite yield similar 360 (and 320) Ma ages.

An Introduction to Mass Spectrometry Ionization: An …

The sample is placed on a probe, which is then inserted into the ionization region of the mass spectrometer, typically through a vacuum interlock. ... The principal problems associated with thermal desorption in electron …

Thermal Ionization Mass Spectrometer (TIMS) | SpringerLink

A thermal ionization mass spectrometer (TIMS) consists of (1) an ion source (here a solid source), (2) a magnet (analyzer) that splits the ions depending on …

Thermal Ionization Mass Spectrometry (TIMS) | Wiley …

This first book to discuss both separation chemistry and mass spectrometry for mineral and rock analysis compares the two frequently used techniques, analyzing both their scope and limitations by way of numerous practical examples. The excellent and highly experienced author adopts a comprehensive and systematic approach, reviewing all the …

Composition of Ultrafine Particles in Urban Beijing

The thermal desorption chemical ionization mass spectrometer (TDCIMS) can semicontinuously measure UFP composition at the molecular level. We modified a TDCIMS and deployed it in urban Beijing. Radioactive materials in the TDCIMS for aerosol charging and chemical ionization were replaced by soft X-ray ionizers so that it can be …

A Brief History of Mass Spectrometry | Analytical Chemistry

Thomson's early work on cathode rays laid the foundation of the MS field. Ultimately, Thomson, with the help of his protégé Francis Aston (who would go on to win his own Nobel Prize in Chemistry in 1922 ), built what later would be recognized as the first mass spectrometer to measure the masses of charged atoms.